Monday, 18 February 2013

UNIPULSE CONTROLLER TECHNICAL SPECIFICATION




UNIPULSE CONTROLLER TECHNICAL SPECIFICATION

I.ANALOG SECTION       

       (i) Load cell excitation       :   DC10V+/5%(enables to switchover from 5V to 10)
         output current: within 120 mA
         4-wir standard, 6-wire remote sensing
         (4-350 ohm loadcell, when excitation is 10V)

(ii)Zero/span adjustment   :   Zero adjustment range: 0 to approx. 2 mV/V
          Span adjustment range: 0.3 to 2.0 mV/V

      (iii)Min.input sensitivity      :  0.3 micron V/count (at invalid ¼ scale division)
                                              0.075 micron V/count (at invalid ¼ scale division)

(iv)Accuracy                        :  Non-\Linearity    : within 0.01%FS
    (Type: 0.005% FS at room Temperature)
                                                         :  Zero drift             : within 0.1 micron V/ºC RTI
                                                                                       (Typ: 0.08 micron V/ºC)
                                                      :  Gain drift            : within 15 ppm/ºC
                                                                                           (Typ: 5ppm/ºC
                                                      :   Noise                 : within 0.1 micron Vp-p RTI       
                                                                                          (0.1 Hz to 10Hz)
(v)Analog filter                                                                                                                             
    A/D Converter                          : 
Bessel low-pass filter (-12dB oct) selected at 2,4,6,8, Hz
                  
                                                            Speed             : 1000 times/second (5ms)
     (Enables to switchover from 200       
     times/second to 1000 times/second)
                                                      : Resolution         : 16 bit (Binary)

  (vi)Display resolution                  : 1/10000 (at valid ¼ scale division )
                                              1/40000 (at valid ¼ scale division)
  (vii)Secondary calibration           :  Digital calibration ( Registration of reference value)
                                                                                         
II.SETTINGS
(i)Setting method                 :  Analog type touch screen panel setting
                                      or setting from host computer via Rs-232C

(ii)Memory                          :  Initial setting    : NOV RAMS (nonvolatile RAM)
                                                  other setting     : Lithium battery back-up C-MOS   
                                                   RAM

(iii)Protection of set
            Values      :    Initial set values and calibration can be protected from
                            unauthorized access.

     (iv) Setting item                * Code’’’ Final, Over, Under, CPS, SP1, Auto Free Fall   
                                               comparison. Compensation Feeding Time, Accumulate    
                                               Clear, Total Comparison, total limit, count limit.
                                        
                                            * Comparison’’’ U/L limit Comparison1.Limit Comparison,
                                               2. Upper limit, 3. Lower limit, Near Zero comparison,                                                    Near Zero, Over/Under comparison 1. Over/Under  
                                               Comparison 2.complete signal output,


                                           *complete output Time, Judging Time, comparison      
                                              Inhibit Time,’ Discharging Control Mode, Auto Free Fall
                                               Compensation, average count of AFFC.

                                           * Operation’’’ Display Frequency, Digital Filter 1.Anlog    
                                              Filter, Digital Filter 2, Motion Detection Mode, Motion
                                               Detection (period), Motion Detection (Range), Zero
                                              Tracking (Range).
                                         
                                           * DZ Regulation Value.

                                           * Sequence mode’’’ Sequence mode, judging Times, AZ           
                                             Times, at start NZ Confirmation, At Start Weight value
                                             Confirmation, Adjust Feeding,

                                           * Discharge gate Control, Discharge Time, START, STOP
                                              Key.

                                            * Function’’’ Preset Tare Weight, 1. Preset Tare weight,
                                              2. TARE SHEET, Auto Accumulation Commend,
                                              Weighing Code Selection, Setting Code, Selection,      
                                              Gross/Net Selection, Discharge Control Mode, TARE/                                             
                                              DZ Key, GROSS/NET Key, Each code key.

                                             *  Extended Function’’’ Accumulation Commend, One-
                                               Touch Tare Subtraction, Range of Tare Subtraction,
                                               Tare Display, Extended preset Tare Subtraction,
                                               Over Scale.

                                            * Calibration’’’  Zero Calibration. Balance Weight Value,
                                               Capacity, Minimum Scale Division, Equivalent   
                                              Calibration, Net Over. Gross Over, Decimal Place,
                                               Unit Display, ¼ Scale Division Display, Gravitational
                                              Acceleration, Load cell Excitation.

                                            * Graph’’’ Graphic Mode, Trigger Level, X End Point,
                                              Start Point, Y End Point.

                                             * Data’’’ Average Weight, Maximum Weight, Minimum
                                              Weight, General Standard Deviation, Count of Data
                                              Latest

                                             * Data, Max,-Min,

                                             * Communication’’’ Baud rate, The Lenth of character,    
                                              Parity Bit, Stop.

                                             * Bit, Terminator, SIFII ID

                                             * System’’’ back Light On, Back Light OFF, LOCK (soft),
                                               Self

                                             * Check, System speed, Language, Password.


III.Display

      (i) Display                          :  STN color LCD (Display area 117 2W*88.4H mm) 320*240 dot

     (ii) Weight value display        :  5 digits.  Signs: Minus sign on most Significant digit.

     (iii) Unit                             :  Selectable t, kg, g, N, Ib none.

     (iv) Decimal point                  :   Selectable 0, 0.0, 0.00, 0.000

     (v) Display update rate         :   Selectable 3, 6, 13, 25 times/etc

     (vi)Scale capacity                 :   5 digits (up to 99999)

     (vii)Over display                :    LOAD (A/D converter over scale), OFL1
                                                     (Net Weight: Net over set value)
                                                     OFL2 (Gross weight – capacity – 9 scale divition),
                                                     OFL2 (gross weight- Gross over set value)

     (viii)  Center zero              :   CZ’’turns on when the displayed value is at the center
                                                      of zero (0 +/-1/4 scale)

      (ix) Status display            :    LACK, HOLD, ZALM, STAM, TARE, RUN, HI, LO, NZ,
                                                           SP1, SP2, SP3, OVER, GO, UNDER, COMPL, DCHG,
                                                               AUTO

      (x) Set value display         :   CODE, FINASL, SP1, SP2, CPS, UNDER, OVER

      (xi) Accumulation display :    Accumulating times… 4 digits, Accumulating value…
                                                  9 digits.

      (xii) No. display               :    Alarm No. (2 digits)…Error No. in sequence control
                                                     Sequence No. (3 digits)… Process No. in sequence  
                                                     Control.


a)    Weight indicator
b)   Weight value display
c)    Maximum scale value
d)   Minimum scale value
e)    Over scale display
f)     Centre zero display
g)    Status indicator and display
h)   Set value and accumulated value display




IV.I/O SECTION

(i) External                            : Output signal circuit is an open controller output of a
    Output signal                          Transistor. Near Zero, SP1, SP2, SP3, Under, Go, Over,             
                                                  Complete Discharge, Lower Limit, Upper Limit, Stable,       
                                                  Weight error, error, Final error, Run or Total limit,

(ii) External                           :  Inputted by shorting or opening input and COM
     Input Signal                           Terminals. G/N, D/Z, ON, Tare OFF, Hold Or Judge,
                                                   Feed/Discharge, Accumulation Commend,
                                                  Accumulation clear, Start, Stop, Discharge commend
                                                  Code No, Designation, Compulsory Discharging
                                                  Commend, Open Discharge gate, Close Discharge Gate,
                                                  Code No. Designation, Selection, Graph Drawing.



(iii) Weighing Code Selection input
                                                 BCD 2 digits * 00 to 99∙100 codes.     


V.INTERFACE

       SIP     2-wire serial interface (SI/F)’’’ Connect Controller to printers and remoter                
                 displays (up to 3 units)

       232    RS-232C Communication interface’’’ (option)’’’ Transmits weight data, and            
                 set values can be written or read by a host computer
                                              
NOTE  :- The  above mentioned output, and accuracy will be subject to the full fillment of following conditions.

        1)    Uniform inflow of material.
        2)    Sufficient air pressure.
        3)    Material free from moisture and lumps.
        4)    Machine should be free from vibration.    
        5)    Proper earthing of Load cells with separate earth pit.

                                                                                
                                                                         For Hi-Tech Engineers

No comments:

Welcome to Hi - Tech Engineers

Welcome to Hi - Tech Engineers