1
|
Controller
Make
|
FLINTEC
GERMAN MAKE
|
|
2
|
Model
|
FT
-13
|
|
|
|
|
|
3
|
A/D Converter
|
|
|
|
A/D converter Type
|
24 Bit Delta-Sigma
Ratio metric with integral analog and digital filters.
|
|
|
|
|
|
|
Conversion Rate
|
Max. 400
measurement values/s
|
|
|
Input Sensitivity
|
0.4 µ V/e (90/384/EC
directive); 0.83 µ V/e
(2004/22/EC Directive;
|
|
|
|
0.1 µ V/d (non approved)
|
|
|
Analog.inp.range
|
0 to 20m V
|
|
|
Internal Resolution
|
up to 8 000 000
|
|
|
Display Resolution
|
up to 60 000
|
|
|
|
|
|
4
|
Accuracy
|
|
|
|
Accuracy Class
|
III
|
|
|
EU Type Approved
|
10 000 intervals
(90/384/EC directive); 6 000 (2004/22/E directive);
|
|
|
|
Single range.
|
|
|
|
|
|
5
|
Display and
Keyboard
|
|
|
|
Display
|
6 Digits, 7
Segments, LED Red, 20mm high (Panel
type 14mm high)
|
|
|
Keyboard
|
18 keys; membrane
with tactile feed back.
|
|
|
|
|
|
7.
|
Digital
Filter
|
10
step adjustable
|
|
8.
|
Filling
Programmed
|
7
standards
|
|
9.
|
Weighing
Functions
|
Tare,
zero, motion, auto zero tracking
|
|
10.
|
Digital
I/O
|
4x
in / 8x out
|
|
11.
|
Linearity
|
within
0.0015% FS, 2ppm/C
|
|
|
|
|
|
12.
|
Load Cells
|
|
|
|
Excitation
|
5V DC at 58…1200 ;
max.100mA
|
|
|
Number of Load
cells
|
up to 6 load cells
(350 ) or 18 load cells (1 100 ) in parallel
|
|
|
Connections
|
4- or 6-wire
technique; cable length 574 m/mm2 for 6 wire connection
|
|
|
|
|
|
13.
|
Communication
|
standard serial
interface RS 232C; 1 200 to 57 600 baud;
|
|
|
|
|
|
14.
|
Power Supply
|
200…240V AC, 50/60
Hz OR 12 V DC, Max. 12VA
|
|
|
|
|
|
16.
|
Environment and
Enclosure
|
|
|
|
Operation temp
|
to 4C Legal for trade; 85% RH max,
non-condensing
|
|
|
Enclosure
|
Panel Type or
Stainless Steel.
|
|
|
|
|
Continued… Page -2
Page -2
Key features:
4
EU
Type approved for 10 000 intervals in single range scales (90/384/EC) and for 6 000 intervals in single
range scaled ( 2004/22/EC)
4 Approved sensitivity of 0.4 µ V/e (according 90/384/EC directive) and 0.83 µ V/e (according 2004/22/EC directive); non-approved
sensitivity of 0.1 µ V/d.
4 Internal
resolution up to 8 000 000 counts.
4 Display
resolution up to 60 000 counts.
4 Maximum
conversion rate of values/s (After serial no. 520001 G7)
4 Adaptive
digital filter for fast and stable reading.
4 High
resolution display mode.
4 Up
to 6 load cells (350Ω) or 18 load cells (1100 Ω)
4 Real
time clock
4 Standard
serial interface RS 232C.
4 Integrated
AC Power Supply.
4 Zeroing
with one button & tarring with one button.
4 Auto
Zero Tracking.
4 Motion
detection.
4 4x
isolated digital inputs/8x isolated digital outputs.
4 7
standard filling programmed.
4 Key
lock option to prevent unauthorized access.
Available Option:
4
Additional serial interface RS 232 C/20 mA TTY
CL/RS485 (20mA TTY CL not for stainless steel housing)
4 Modbus
RTU.
4 Ethernet
TCP/IP and Modbus TCP.
4 Profibus
DP-V0 & DP – V1.
4 4x
isolated digital inputs/8x isolated digital outputs (required customized
firmware)
4 12V
DC Power inlet.
For Hi-Tech Engineers