Monday, 18 February 2013

Bagging Machine Hi-Tech Micro-Processor based weig...


1
Controller Make
FLINTEC GERMAN MAKE
2
Model
FT -13



3
A/D Converter


A/D converter Type
24 Bit Delta-Sigma Ratio metric with integral analog and digital filters.




Conversion Rate
Max. 400 measurement values/s

Input Sensitivity
0.4  µ V/e (90/384/EC directive); 0.83 µ  V/e (2004/22/EC Directive;


0.1  µ V/d (non approved)

Analog.inp.range
0 to 20m V

Internal Resolution
up to 8 000 000

Display Resolution
up to 60 000



4
Accuracy


Accuracy Class
III

EU Type Approved
10 000 intervals (90/384/EC directive); 6 000 (2004/22/E directive);


Single range.



5
Display and Keyboard


Display         
6 Digits, 7 Segments, LED Red, 20mm  high (Panel type 14mm high)

Keyboard
18 keys; membrane with tactile feed back.



7.
Digital Filter
10 step adjustable
8.
Filling Programmed
7 standards
9.
Weighing Functions
Tare, zero, motion, auto zero tracking
10.
Digital I/O
4x in / 8x out
11.
Linearity
within 0.0015% FS,  2ppm/C



12.
Load Cells


Excitation
5V DC at 58…1200 ; max.100mA

Number of Load cells
up to 6 load cells (350 ) or 18 load cells (1 100 ) in parallel

Connections
4- or 6-wire technique; cable length 574 m/mm2 for 6 wire connection



13.
Communication
standard serial interface RS 232C; 1 200 to 57 600 baud;



14.
Power Supply
200…240V AC, 50/60 Hz OR 12 V DC, Max. 12VA



16.
Environment and Enclosure


Operation temp
 to 4C Legal for trade; 85% RH max, non-condensing

Enclosure
Panel Type or Stainless Steel.







Continued… Page -2



Page -2


Key features:


4  EU Type approved for 10 000 intervals in single range scales (90/384/EC) and for 6 000 intervals in single range scaled ( 2004/22/EC)
4  Approved sensitivity of 0.4 µ V/e (according 90/384/EC directive) and 0.83 µ V/e (according 2004/22/EC directive); non-approved sensitivity of 0.1 µ V/d.
4  Internal resolution up to 8 000 000 counts.
4  Display resolution up to 60 000 counts.
4  Maximum conversion rate of values/s (After serial no. 520001 G7)
4  Adaptive digital filter for fast and stable reading.
4  High resolution display mode.
4  Up to 6 load cells (350) or 18 load cells (1100 )
4  Real time clock
4  Standard serial interface RS 232C.
4  Integrated AC Power Supply.
4  Zeroing with one button & tarring with one button.
4  Auto Zero Tracking.
4  Motion detection.
4  4x isolated digital inputs/8x isolated digital outputs.
4  7 standard filling programmed.
4  Key lock option to prevent unauthorized access.

Available Option:

4  Additional serial interface RS 232 C/20 mA TTY CL/RS485 (20mA TTY CL not for stainless steel housing)
4  Modbus RTU.
4  Ethernet TCP/IP and Modbus TCP.
4  Profibus DP-V0 & DP – V1.
4  4x isolated digital inputs/8x isolated digital outputs (required customized firmware)